Part Number
Definition:
A VALVE DESIGNED TO AUTOMATICALLY MAINTAIN WITHIN CLOSE LIMITS A PREDETERMINED OUTLET PRESSURE WHICH MAY BE ADJUSTABLE WITHIN A SPECIFIED RANGE REGARDLESS OF THE HIGHER FLUCTUATING OR CONSTANT INLET PRESSURE. IT IS DESIGNED FOR USE WITH COMPRESSED GAS(ES) AND VARIOUS LIQUIDS AND MAY INCLUDE GAUGES. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES REGULATOR, PRESSURE, MEDICAL GAS ADMINISTRATION APPARATUS; REGULATOR, OXYGEN, BAROMETRIC CONTINUOUS FLOW; REGULATOR, OXYGEN DEMAND; REGULATOR, OXYGEN DILUTER DEMAND; AND VALVE(1), FLUID PRESSURE REGULATING, AIRCRAFT.
CAGE Information
Code | Company |
---|---|
78462 | SPORLAN VALVE CO |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEVA | OUTLET PRESSURE RANGE | +0.0/+60.0 POUNDS PER SQUARE INCH |
AEVZ | MAXIMUM INLET PRESSURE RATING | 10.0 POUNDS PER SQUARE INCH |
AGAV | END ITEM IDENTIFICATION | NHA NSN 4110-01-389-9180 REFRIGERATION UNIT,MECHANICAL |
ACKL | MEDIA FOR WHICH DESIGNED | REFRIGERANT R-134A |
FEAT | SPECIAL FEATURES | AEND CONNECTIONS ARE 7/8 INCH ODF; VALVE IS SET FOR A MAXIMUM ALLOWABLE SUCTION PRESSURE OF 40 PSIG; MATERIALS USED SHALL BE COMPATIBLE WITH POLYOL ESTER OIL USED IN R-134A REFRIGERATION SYSTEMS |